D-FL-200.jpg

 

D-FL200 Volume flow measuring system

Measuring system for ultra-sonic measuring of velocity and volume flow, especially for wet and aggressive smoke emissions (waste incineration).

 

Features

    In-situ measuring method

    Measurement possible below dew point and for high dust concentrations

    Continuous measurement of normal volume flow and gas velocity

    Automatic zero point and reference point control

    Direct connection for temperature and pressure correction

    Parameter input via keyboard or PC

    Continuous temperature measuring.

 

Applications

    Volume flow measuring at low speeds

    Plans with damp and/or aggressive exhaust gas, e.g. in waste incineration plants.

    Volume flow measurement at high dust content.

 

Approvals

    Suitability-tested by the TUV Hamburg, test report 99CU019

    Itemized in the list of suitable measuring devices for continuous emission measuring

    MCERTS pending.

 

Measuring principle

The D-FL 200 measuring system works according to the acoustic transit time differential method. Ultrasonic transducers mutually send and receive short pulses with and against the gas flow direction which affects their transit time. The volume flow is calculated from the difference of transit times.

 

Options

    Modbus interface

    Temperature transducer

    Absolute pressure transducer

    Weather protection covers

    Purge air sensor with potential free error contact.